⸺ SPORT / IN-DEPTH ARTICLE

Neuralign in sport: from functional assessment to neuromuscular control

In overhead sports, the shoulder is repeatedly exposed to movements requiring speed, mobility and coordination. Performance depends not only on strength and range of motion, but also on the interplay between the rotator cuff, periscapular muscles, scapular movement and neuromuscular control. Alongside the clinical examination, it is therefore useful to assess and measure shoulder function and dynamic control.

The “Neuralign and Sport” document describes a pathway that links dynamic assessment, intervention targeting motor control and reassessment. Showmotion and Shoulder Pacemaker contribute to different stages of this process under the guidance of a healthcare professional.

Scapular control in overhead athletes

Scapular dyskinesis describes an observable alteration in scapular movement or position. A systematic review cited in the document reported a prevalence of 61% among overhead athletes, compared with 33% among non-overhead athletes [1]. However, its presence does not automatically indicate pathology: in some cases, it may reflect adaptation to sport-specific movement.

The evidence linking scapular dyskinesis to the risk of pain or injury is not conclusive. One meta-analysis found an increased relative risk of future shoulder pain in asymptomatic athletes with dyskinesis [2]. A subsequent review, however, did not identify scapular dyskinesis as a statistically significant independent risk factor [3]. The clinical significance of scapular movement should therefore be interpreted alongside strength, mobility, symptoms, injury history and training loads.

Showmotion: making movement measurable

Showmotion collects scapulohumeral kinematic measurements through wearable sensors, adding quantitative information about shoulder behaviour during movement tasks to the clinical assessment. In sports settings, one potential application is to establish an individual baseline against which subsequent assessments can be compared.

Repeated measurements may help staff monitor changes in movement strategies during a training or rehabilitation programme. Consistent testing procedures and conditions are needed to make these comparisons meaningful. Instrumented measurements do not replace clinical judgement, but they can help inform it.

Valutazione del movimento della spalla con sensori Showmotion

Showmotion · movement measurement

Shoulder Pacemaker: stimulation during active movement

Shoulder Pacemaker combines voluntary movement with neuromuscular stimulation synchronised with the task. The aim is to facilitate activation of selected muscle groups during a motor task, rather than inducing a passive contraction separately from exercise.

Device-specific evidence includes a proof-of-concept study on the treatment of functional shoulder instability [4] and a prospective clinical study of 21 cases in 14 patients with functional posterior shoulder instability. The latter reported improvements in key clinical outcome scores maintained during follow-up for up to 24 months, within the population and treatment protocol studied [5].

The document also cites a randomised study involving amateur female handball players with scapular dyskinesis. Combining scapular retraction exercises with neuromuscular electrical stimulation (NMES) produced favourable outcomes for certain parameters compared with exercise alone [6]. This study concerns NMES in general and must not be presented as direct validation of Shoulder Pacemaker.

Esercizio sportivo con Shoulder Pacemaker

Shoulder Pacemaker · application in sport

From treatment to the sports setting

When working with athletes, functional assessment and neuromuscular retraining may be relevant in different settings, from the rehabilitation of motor control impairments to movement monitoring during the season. Their inclusion in conditioning or risk-factor reduction programmes requires goals, indications and progressions defined by the healthcare team.

Injury prevention cannot be reduced to a single measurement. Literature on overhead sports considers several modifiable factors and reports heterogeneous findings on prevention programmes [7, 8, 9]. The primary value of measurement is therefore the ability to document an individual profile and monitor how it changes, not to promise to predict or prevent injury.

Measure → Train → Re-measure

The integrated approach proposed by the Neuralign platform follows three stages: first, measure function and establish a baseline with Showmotion; then, when indicated, intervene through an active programme that may include Shoulder Pacemaker; finally, reassess movement with repeatable tests to compare measurements, evaluate the effectiveness of the programme and guide subsequent decisions.

For physiotherapists, medical staff and performance teams, a potential benefit of this approach is access to comparable measurements that can be considered alongside other clinical and sports-related indicators. The aim is to make clinical decisions better documented and the pathway more individualised, while keeping professional interpretation central.

References

[1] Burn MB, McCulloch PC, Lintner DM, Liberman SR, Harris JD. Prevalence of Scapular Dyskinesis in Overhead and Nonoverhead Athletes: A Systematic Review. Orthop J Sports Med. 2016;4(2):2325967115627608. DOI: 10.1177/2325967115627608.

[2] Hickey D, Solvig V, Cavalheri V, Harrold M, McKenna L. Scapular dyskinesis increases the risk of future shoulder pain by 43% in asymptomatic athletes: a systematic review and meta-analysis. Br J Sports Med. 2018;52(2):102–110. DOI: 10.1136/bjsports-2017-097559.

[3] Hogan C, Corbett JA, Ashton S, Perraton L, Frame R, Dakic J. Scapular Dyskinesis Is Not an Isolated Risk Factor for Shoulder Injury in Athletes: A Systematic Review and Meta-analysis. Am J Sports Med. 2021;49(10):2843–2853. DOI: 10.1177/0363546520968508.

[4] Moroder P, Minkus M, Böhm E, Danzinger V, Gerhardt C, Scheibel M. Use of shoulder pacemaker for treatment of functional shoulder instability: Proof of concept. Obere Extrem. 2017;12:103–108. DOI: 10.1007/s11678-017-0399-z.

[5] Moroder P, Plachel F, Van-Vliet H, Adamczewski C, Danzinger V. Shoulder-Pacemaker Treatment Concept for Posterior Positional Functional Shoulder Instability: A Prospective Clinical Trial. Am J Sports Med. 2020;48(9):2097–2104. DOI: 10.1177/0363546520933841.

[6] Espejo-Antúnez L, Gutiérrez-Coronado J, Fernández-Morales C, Albornoz-Cabello M, Prato LF, Cardero-Durán MÁ. Effects of NMES-Guided Scapular Retraction Exercise Program in Amateur Female Handball Players with Scapular Dyskinesis Without Shoulder Pain: A Randomized Controlled Clinical Trial. J Clin Med. 2025;14(15):5567. DOI: 10.3390/jcm14155567.

[7] Hoppe MW, Brochhagen J, Tischer T, Beitzel K, Seil R, Grim C. Risk factors and prevention strategies for shoulder injuries in overhead sports: an updated systematic review. J Exp Orthop. 2022;9(1):78. DOI: 10.1186/s40634-022-00493-9.

[8] Hadjisavvas S, Efstathiou MA, Malliou V, Giannaki CD, Stefanakis M. Risk factors for shoulder injuries in handball: systematic review. BMC Sports Sci Med Rehabil. 2022;14(1):204. DOI: 10.1186/s13102-022-00588-x.

[9] Wright AA, Ness BM, Donaldson M, Hegedus EJ, Salamh P, Cleland JA. Effectiveness of shoulder injury prevention programs in an overhead athletic population: A systematic review. Phys Ther Sport. 2021;52:189–193. DOI: 10.1016/j.ptsp.2021.09.004.

The epidemiological data describe associations within specific populations and do not demonstrate that scapular dyskinesis alone causes injury. Device use should be determined by healthcare professionals within the scope of the respective intended uses and regulatory authorisations.

⸺ Restricted access
Neuralign content is intended for healthcare professionals
This website presents medical devices and clinical information intended for doctors and physiotherapists. Please confirm your profile to continue.